Configuring the product[Nicht freigegeben]

The tasks described in this section may only be carried out by a qualified electrician.

In the top section of the housing, there are two 8-pin DIP switches, with which the device can be configured. In the delivery state, all DIP switches are switched off ("OFF"). On delivery, the product is ready for connection.

DIP switch (delivery state)

1

Bank S1

2

Bank S2

The following functions can be set via the DIP switches:

Bank S1

DIP switch

Function

1

LED display colour scheme

  • "OFF":
    • "Standby" symbol = blue
    • "Charging" symbol = green
  • "ON":
    • "Standby" symbol = green
    • "Charging" symbol = blue

2

Unbalanced load limitation

  • "OFF": Unbalanced load limitation off
  • "ON": Unbalanced load limitation on

3

Authorisation

  • "OFF": No authorisation (Autostart)
  • "ON": Authorisation via the enable input

4, 5, 6, 7, 8

Without function

3

Authorisation

  • “OFF”: No authorisation (Autostart)
  • “ON”: Authorisation through RFID

4

Using Modbus RTU

  • “OFF”: Modbus RTU is not used
  • “ON”: Modbus RTU is used

5

Master / Satellite

  • “OFF”: Configuration as master
  • “ON”: Configuration as satellite

6

Type of energy meter

  • “OFF”: Siemens PAC1600 7KT1661
  • “ON”: TQ Energy Manager EM 420 / KOSTAL Smart Energy Meter

7

Solar charging

  • “OFF”: Solar charging deactivated
  • “ON”: Solar charging activated

8

Without function

Bank S2

DIP switch

Function

1, 2, 3

Max. charging current

4, 5

Reduced charging current when downgrade input is energised

6,7,8

Max. amperage - building connection

6,7,8

Without function