Installing the product on the wall[Nicht freigegeben][Bisher nicht für die Übersetzung exportiert]
ATTENTION

Material damage due to uneven surface
Installing on an uneven surface can cause the housing to go out of shape, so that the protection class is no longer guaranteed. Consequential damage of electronic components can occur.
- Only install the product on an even surface.
- If necessary, level out uneven surfaces with suitable measures.
MENNEKES recommends installing at an ergonomically sensible height depending on the height of the body. |
The fastening materials provided (screws and dowels) are only suitable for installation on concrete, brick or wooden walls. |
ATTENTION

Material damage due to drilling dust
Consequential damage of electronic components can occur if drilling dust gets into the product.
- Make sure that drilling dust does not get into the product.
- Do not use the product as a drilling template and do not drill through the product.
- Create the drill holes using the drilling template (included in the delivery contents) or first mark the drill holes using the illustration “Drilling dimensions [mm]” and then drill them. The diameter of the holes depends on the chosen mounting hardware.
- Using a suitable tool, break out the required cable entry point at the predetermined location.
- Insert the compatible membrane gland (included in delivery) into the respective cable entry point.
Cable entry point | Membrane gland |
---|---|
Top side and bottom side | Membrane gland with strain relief |
Reverse side | Membrane gland without strain relief |
For and supply line with an outer diameter ≥ 17 mm only: top side and bottom side |
Tightening torque: 3 Nm |
- Insert the supply line into the product through the respective cable entry point together with the control / data line (if applicable).
Approx. 30 cm of cable is required for the supply line inside the product. |
- Fasten the product to the wall using dowels and screws. Select the tightening torque according to the building material of the wall.
- Check the product for firm and secure attachment.
Sealing plugs
- Cover fastening screws with the sealing plugs (1) (included in the scope of delivery).
ATTENTION

Material damage due to missing sealing plugs
If the fastening screws are not covered, or are not adequately covered with the sealing plugs provided, the specified protection class and IP rating are no longer guaranteed. This can lead to consequential damage of electronic components.
- Cover fastening screws with the sealing plugs.
ATTENTION

Material damage due to missing sealing plugs
If the fastening screws are not covered, or are not adequately covered with the sealing plugs provided, the specified IP rating is no longer guaranteed. This can lead to consequential damage of electronic components.
- Cover fastening screws with the sealing plugs.