Connection and configuration[Nicht freigegeben]

Connecting an external energy meter

The product is compatible with the following energy meters:

  1. Install the external energy meter in the upstream electrical installation.
  2. Connect the energy meter and the product with a data cable.

Connecting the data line (Modbus RTU)

Configuration

For solar charging, the following settings have to be made using DIP switches:

DIP switch (bank S1)

Required configuration

Brief description

4

ON

Using Modbus RTU

5

OFF

Master

6

Dependent on energy meter

  • “OFF” = Siemens PAC1600 7KT1661
  • “ON” = TQ Energy Manager EM 420 / KOSTAL Smart Energy Meter

7

ON

Solar charging activated

Configuration tool:
If the energy meter is to measure external consumers only, an additional setting has to be made in the configuration tool (“Meter measuring point” parameter).

Description of the configuration tool

Blackout protection:
Blackout protection is enabled automatically for solar charging, which is why the max. amperage provided by the building connection must also be set via the DIP switches.

Blackout protection

Selecting the charging mode

Sun button

Press the Sun button (1) to select the charging mode according to the following diagram.

Switching the charging modes

The set charging mode is indicated by the “Sun” (2) LED:

Status of “Sun” LED

Set charging mode

Off (is not lit)

Standard mode

Lights up

Sunshine mode

Pulsates

Sunshine+ mode

  • The Sun button has no function unless solar charging has been set up.

The following information applies to both the 22 kW and 11 kW variants with enabled dynamic phase switchover:

  • Switching between Standard mode, Sunshine mode and Sunshine+ mode is always possible (also while charging is in progress).

The following information applies to the 11 kW variant with disabled dynamic phase switchover:

  • Switching between Sunshine mode and Sunshine+ mode is always possible (also while charging is in progress).
  • Switching between Standard mode and Sunshine(+) mode is not possible while charging is in progress. The vehicle must be disconnected from the charging station before switchover.