Technical data
|
|
|
---|---|---|
Max. charging power [kW] | 11 | 22 |
Rated current InA [A] | 16 | 32 |
Rated current of a charging point Mode 3 InC [A] | 16 | 32 |
Max. back-up fuse [A] | 20 * | 40 * |
Conditional rated short-circuit current Icc [kA] | 1.1 | 1.8 |
* For the design of the maximum back-up fuse, the regulations applicable at the installation site must be observed.
AMTRON® Compact 2.0 11, AMTRON® Compact 2.0 22 | |
---|---|
Connection | single phase |
Nominal voltage UN [V] AC ±10 % | 230 |
Nominal frequency fN [Hz] | 50 |
Nominal insulation voltage Ui [V] | 500 |
Nominal impulse withstand voltage Uimp [kV] | 4 |
Nominal diversity factor RDF | 1 |
Types of system earthing | TN / TT (IT under certain conditions) |
EMC classification | A+B |
Protection class | I |
IP rating | IP 44 |
Overvoltage category | III |
Mechanical impact protection | IK10 |
Contamination rating | 3 |
Installation | Outdoor or indoor |
Stationary / movable | Stationary |
Use (according to IEC 61439-7) | AEVCS |
External design | Wall mounted |
Dimensions H x W x D [mm] | 360.5 x 206.9 x 145.6 |
Weight [kg] | 5.1 |
Standard | IEC 61851, IEC 61439-7 |
The specific standards according to which the product was tested can be found in the declaration of conformity for the product. The declaration of conformity can be found on our website in the download section for the selected product.
Supply line terminal strip | |||
---|---|---|---|
Number of terminals | 3 | ||
Conductor material | Copper | ||
| Min. | Max. | |
Clamping range [mm²] | rigid | 0.2 | 10 |
flexible | 0.2 | 10 | |
with ferrule | 0.2 | 6 | |
Tightening torque [Nm] | 0.8 | 1.6 |
Enable input terminals | |||
---|---|---|---|
Number of terminals | 2 | ||
Specification of the external switching contact | Potential-free (NO) | ||
| Min. | Max. | |
Clamping range [mm²] | rigid | 0.5 | 4 |
flexible | 0.5 | 4 | |
with ferrules | 0.5 | 2.5 | |
Tightening torque [Nm] | 0.8 | 1.6 |
Downgrade input terminals | |||
---|---|---|---|
Number of terminals | 2 | ||
Specification of the external switching contact | Potential-free (NC) | ||
| Min. | Max. | |
Clamping range [mm²] | rigid | 0.5 | 4 |
flexible | 0.5 | 4 | |
with ferrules | 0.5 | 2.5 | |
Tightening torque [Nm] | - | - |
Switching output for shunt release terminals | |||
---|---|---|---|
Number of terminals | 2 | ||
Max. switching voltage [V] AC | 230 | ||
Max. switching voltage [V] DC | 24 | ||
Max. switching current [A] | 1 | ||
| Min. | Max. | |
Clamping range [mm²] | rigid | 0.5 | 4 |
flexible | 0.5 | 4 | |
with ferrules | 0.5 | 2.5 | |
Tightening torque [Nm] | - | - |
Modbus RTU terminals | |||
---|---|---|---|
Number of terminals | 3 x 2 | ||
| Min. | Max. | |
Clamping range [mm²] | rigid | 0.5 | 4 |
flexible | 0.5 | 4 | |
with ferrules | 0.5 | 2.5 | |
Tightening torque [Nm] | - | - |